대한전기학회:학술대회논문집 (Proceedings of the KIEE Conference)
- 대한전기학회 1995년도 추계학술대회 논문집 학회본부
- /
- Pages.264-267
- /
- 1995
회전자 자속 이탈각 추정을 이용한 유도전동기의 회전자 시상수 보상
Rotor Time Constant Compensation of Induction Motor by Estimating Deviation Angle
- Cha, Young-Kil (Dept. of Electrical Eng. Kyung-Pook National Univ) ;
- Jung, Jong-Jin (Dept. of Electrical Eng. Kyung-Pook National Univ) ;
- Kim, Heung-Geun (Dept. of Electrical Eng. Kyung-Pook National Univ)
- 발행 : 1995.11.18
초록
In indirect vector control, if the value or the rotor tine constant used in slip calculation is different from the actual rotor time constant because of the temperature rising and flux saturation level, model flux angle and actual flux angle is different so that the transient and steady state response is degraded. In this paper, flux deviation angle is calculated by using actual torque and reference torque, and this flux deviation angle is summed to slip angle, therefore rotor flux angle is always accurate and indirect vector control is satisfied.
키워드