Analysis on the Circumference Wall Temperature in a Long Horizontal Pipe with Thermal Stratification

  • 발행 : 1995.10.01

초록

The One-dimensional fin model is used to analyze the angular wall temperature variation of long horizontal lines, where stratification could result in top-to-bottom differences in wall temperatures. The top and bottom sections are treated separately and coupled by boundary conditions. The thermal stratification analysis is focused on the effects of the heat transfer rates at the pipe surface. The results show that the heat transfer rate at the pipe surface is the controlling parameter which reduce significantly the temperature difference in pipe circumferential direction. The one-dimensional fin modelling analysis results are verified by comparison with the operating PWR test data. The circumferential temperatures of pipe calculated by one-dimensional fin modelling agree well with the PWR plant test data.

키워드