Vibration of Massive Tunnel Structure Induced by Subway Operation

지하철 운행에 의한 중량터널의 진동

  • Published : 1995.04.01

Abstract

Problems of noise and vibration induced by subway operation became one of the major factor when new subway 1 me is under consideration. One of the most economic method in reducing the noise and vibration is the increasement of the tunnel mass. . Vibration of the massive tunnel structure has been measured induced by subway operation. STEDEF system which was adopted by Seoul Metropolitan Subway Bureau has been proved that more than 99% of the vibration has been decreased at the bottom of the railway track. Most of the vibration measured inside and outside of the tunnel showed that their peak frequency is around SOHz or 100Hz. The propagation characteristics of vibration in massive tunnel , wave propagate in three directions. Overall frequency in the range of 0 to 125H2 horizontal transmission usually increase, while vertical transmission decreases about 50% in the range of 0 to 25Hz and 90Hz to 125Hz regardless of modal shape.

Keywords