한국콘크리트학회:학술대회논문집 (Proceedings of the Korea Concrete Institute Conference)
- 한국콘크리트학회 1995년도 가을 학술발표회 논문집
- /
- Pages.329-333
- /
- 1995
매스콘크리트의 파이프 쿨링 효과
A Study on the Effect of Pipe Cooling in Mass-Concrete
초록
The usual methods for the temperature control of mass-concrete structures include the use of low-heat cement, pre-cooling, or pipe-cooling. In order to control the heat of hydration of mass-concrete structures such as massive pier or anchor block, and mat foundation, the pipe cooling method is widely acceptable for pratical use. In this paper, method of analysis using the Finite Element Method was applied to analyze the heat exchange on the field of three dimensional thermal conduction. The result of analysis Well agreed with experimentally measurement data by "KUMATANI". The method of this analysis will be used widely to control the heat of hydration by the pipe cooling in mass-concrete.-concrete.
키워드