Test of Dynamic Pressurizer Model for CANDU Reactor System Simulation

  • Lee, S.H. (Electric Power System Lab Institute for Advanced Engineering) ;
  • Lim, J.C. (Electric Power System Lab Institute for Advanced Engineerin) ;
  • Park, J-W. (Electric Power System Lab Institute for Advanced Engineering)
  • Published : 1993.11.01

Abstract

In nuclear power plants using pressurized water as the main coolant, it is necessary to maintain system pressure within operational range. During transients, the coolant shrinks and expands causing insurge and outsurge of coolant in the pressurizer. In CANDU system, the pressure is controlled mainly by the pressurizer/degasser-condenser system. In CANDU system, the control of heat transport system pressure is achieved by giving heat to the pressurizer by activating the heaters to compensate a diminution in pressure or by removing heat from the pressurizer by bleeding steam to the degasser-condenser to compensate an increase in pressure. This study aims at developing a theoretical model capable to simulate various operational transients in the CANDU primary heat transport system (PHTS), applicable to CANDU engineering simulator on real time basis.

Keywords