RHEOLOGICAL STUDY ON STRAINER STRUCTURE OF UNDER DRAIN PIPES FOR SLOPE PROTECTION

  • Mihara. Machito (Tokyo University of Agriculture) ;
  • Yasutomi, Rokuro (Tokyo University of Agriculture and Technology) ;
  • Nakamura, Yoshio (Tokyo University of Agriculture)
  • Published : 1993.10.01

Abstract

Pipe drainage is one of the effective slope protein works that can be adopted practically. As fine soil particles are suspended in percolating water, the strainer structure of under drain pipes in necessary to prevent the immediate clogging by soil suspension flow. This study deals with the effective strainer structure of under drain pipes for slope protection. The effective strainer structure of under pipes is the funneled strainer in which pore radius is enlarged toward flow direction. It is designed from the rheological properties of soil suspension flow which prevents the immediate clogging. Experimental results showed that the pipe drain discharge through the funneled strainers was larger than that through the constant pore radius strainers. This theorectial and experimental results indicate that the strainer with enlarged pore radius toward flow direction, is more effective than the strainer with constant pore radius.

Keywords