역기전력에 무관한 가변 히스테리시스 밴드 전류 제어

Adaptive Hysteresis Band Current Control Independent of the Back EMFs

  • 김경화 (한국과학기술원 전기 및 전자공학과) ;
  • 조관렬 (한국과학기술원 전기 및 전자공학과) ;
  • 정세교 (한국과학기술원 전기 및 전자공학과) ;
  • 오동성 (한국과학기술원 전기 및 전자공학과) ;
  • 윤명중 (한국과학기술원 전기 및 전자공학과)
  • 발행 : 1992.07.23

초록

The conventional adaptive hysteresis band current control technique has disadvantages such that on-line calculation of the hysteresis band is very complex, therefore, the adaptive hysteresis band must be stored in the look-up table. In this paper, a new simplified adaptive hysteresis band current control technique with phase decoupling is presented. The adaptive band is independent of the back EMFs. Using this adaptive band and the phase decoupled current error, the modulation frequency is fixed at nearly constant and the PWM inverter has optimal switching pattern.

키워드