대한전기학회:학술대회논문집 (Proceedings of the KIEE Conference)
- 대한전기학회 1991년도 하계학술대회 논문집
- /
- Pages.286-291
- /
- 1991
고압회전기 절연열화진단의 현장적용기술연구
A Study on Site Application Techniques for Insulation Reliability of Rotating Machine
초록
Most of the failures of rotating machine are stator coil insulation failures. The insulation diagnostic testing for high voltage motors and generators are only megger test and P. I Test which is applied DC voltage until now. But it was impossible to judge insulation deterioration status of high voltage rotating machinery by above testing. In other words, even though the megger measurement values are fairly high, they used to be failed from time to time. Therefore in order to excute reliable and detailed diagnosis of insulation deterioration for rotating machinery, the tangent delta test, the alternating current test and the partial discharge test shall be applied to the insulation diagnostic testing on site.
키워드