직류전압 감쇄성분 측정에 관한 CV케이블의 절연열화 예측

Diagnostic method of Insulation Deterioration for CV cable Using D.C. Potential Decay Components

  • 유명호 (서울대학교 전기공학과) ;
  • 한민구 (서울대학교 전기공학과)
  • Yoo, Hyeong-Ho (Department of Electrical Engineering, Seoul National University) ;
  • Han, Min-Koo (Department of Electrical Engineering, Seoul National University)
  • 발행 : 1989.07.21

초록

In this paper, we studied the diagnostic method of insulation deterioration for 22.9kV CNCV cable using D.C potential decay component. At first, arbitrary D.C high voltage is appeied the CNCV cable for two minutes and switched off in vacuum. And then D.C potential decay components is measured for ten minutes. It is detecting source for cable insulation deterioration that its gradient is. Provisionally, we decided the criterion voltage and select the high voltage meter and S.W.