W/Cu 접점과 WC/Cu 접점의 전기적특성과 비교

Electrical properties and a comparison of W/Cu and WC/Cu contacts

  • 이희웅 (한국전기연구소 전기재료연구부 도전.자성재료연구실) ;
  • 변우봉 (한국전기연구소 전기재료연구부 도전.자성재료연구실) ;
  • 한세원 (한국전기연구소 전기재료연구부 도전.자성재료연구실)
  • 발행 : 1988.05.27

초록

Four W/Cu system(60wt%W-40wt%Cu, -0.lwt%Ni, -0.5wt%Ni, -0.lwt%C) and four WC/Cu system(60wt%WC-40wt%Cu, -0.lwt%Ni, -0.5wt%Ni, 0.lwt%C) electrical contacts were prepared by a press-sinter-infiltration process to compare with their properties. Hardness and electrical conductivity are proportional to the refractory metal(W or WC) properties and showed the effect of additives. Arc erosion trend of switch test is changed by current level. High currant test at 1kA showed a different crack formation pattern and erosion mode between W/Cu system and WC/Cu system contacts.

키워드