이격거리가 큰 전극의 공기 절연파괴에 영향을 미치는 인자측정에 관한연구

A Study on the Measurements of Parameters Affecting the Breakdown Mechanism of a Large Air Spacing

  • 조연옥 (한국전기연구소 고전압연구실) ;
  • 최영욱 (한국전기연구소 고전압연구실)
  • Cho, Yun-Ok (High Voltage Lab., KOREA ELECTROTECHNOLOGY RESEARCH INSTITUTE) ;
  • Choi, Young-Wook (High Voltage Lab., KOREA ELECTROTECHNOLOGY RESEARCH INSTITUTE)
  • 발행 : 1988.07.01

초록

The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/${\mu}s$ - 5cm/${\mu}s$, electric field intensity of 2kv/cm, predischarge current of 1.2A - 1.6A, the charges injected into the air gap of 11 - 40 ${\mu}$C for 400-887kV impulse voltages.

키워드